Apartment on Malevycha Street: ventilation with F7 and carbon filtration, Carel humidification, and Daikin ducted air conditioning
Design, installation, and commissioning of indoor climate systems for an apartment: an AEROSTAR air-handling unit custom-built for Ventall with a design airflow of 450 m³/h, F7 filtration plus a carbon filter with 300-400 Pa pressure loss, pressure-switch control to maintain the target air volume, a Carel humidification system, Daikin ducted multi-split air conditioning, and remote and automatic control.
Installation photo report
Technical installation details
Brief execution notes:
For the apartment on Malevycha Street, design, installation, and commissioning of the ventilation, humidification, and air-conditioning system were completed. The solution uses an AEROSTAR air-handling unit custom-built for Ventall with a design airflow of 450 m³/h and F7 filtration plus a carbon filter. Due to pressure losses of 300-400 Pa, pressure-switch control was implemented: the system automatically increases fan speed as filters get dirty to maintain the target design air volume. A Carel humidification system and a Daikin ducted multi-split air-conditioning system with remote and automatic control were also installed.
- Project: apartment on Malevycha Street, Kyiv.
- Ventilation: AEROSTAR custom-built for Ventall, design airflow 450 m3/h.
- Filtration: F7 plus carbon filter.
- Pressure loss across filtration: 300-400 Pa.
- Control logic: pressure switch for maintaining the design air volume; automatic fan speed increase as filters get dirty.
- Humidification: Carel, capacity to be confirmed.
- Air conditioning: Daikin ducted multi-split, capacity to be confirmed.
- Control: remote and automatic.
- Scope: design, installation, commissioning.
Need consultation for your project?
Share your project and task, and we will prepare a technical solution and budget.